Products

1000W 120V DC 8A Output Switching Power Supply with CE

Features: High efficiency, high reliability For AC power supply input global 100% full load and machine test
Output Power
1000W
Output Voltage
120V
Output Current
8A
Input Voltage
AC100-120V/200-240V (Optional)
Brand
SSPELE
Features:
High efficiency, high reliability
For AC power supply input global
100% full load and machine test
Protection characteristics: short circuit/overload/pressure
Built-in dc electric fan forced air cooling
Built-in fan switch control
PFC correction, built-in distance open/shutdown and voltage compensation signal interface
Size: 240*124*65mm(L*W*H)
120V 8A Converter
 
 1000W 120V DC 8A Output Switching Power Supply with CE
model SS-1000
-120
SS-1000
-24
SS-1000
-36
SS-1000
-48
SS-1000
-60
SS-1000
-80
output Dc output voltage 120V 24V 36V 48V 60V 80V
Output voltage tolerance ±1% ±1% ±1% ±1% ±1% ±1%
Rated output current 8A 40A 27A 20A 16A 12A
Output current range 0-8A 0-40A 0-27A 0-20A 0-16A 0-12A
Output power 1000W 1000W 1000W 1000W 1000W 1000W
Ripple and the noise 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
Dc voltage adjustable scope -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10%
Start, rise, keep time 1.5s,50ms,20ms Loaded with
input Input voltage range 100-120VAC or 200-240VAC
Power factor PF>0.95/230VAC PF>0.95/115VAC Loaded with
Exchange input current 7A/115 V 3.5A/ 230 V
efficiency 86% 82% 83% 85% 86% 86%
Impulse current 18A/115V 36A/230V
Leakage current <3.5mA/240VAC
Protection characteristics Overload protection 105%~135%
Protection way: current limiting, automatic recovery
Overvoltage protection 115%~135%
Protection way: hiccups, auto recovery mode
environment Working temperature, humidity -10℃~+50℃;20%~90 %RH
Keep temperature, humidity -20℃~+85℃;10%~95 %RH
Vibrate resistance 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis
security Compression sex 3: KVAC between input and output and input and output KVAC: 1.5 to:
0.5KVAC
Insulation resistance Between the input and output, the input and output, and ground:
100M Ohms/500VDC
standards Insulation resistance Accord with
UL1950,TUV EN60950
EMC standard Accord with
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204
other weight 2Kg
packaging 12pcs/24kg/1.22CUFT
note All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃conditions measuring income value.
Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.
The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index.
Specific output current see output drop forehead curve.

 

Feedback