Output Power
1200W
Output Voltage
24VDC 36VDC 48VDC 60VDC 72VDC 80VDC 100VDC 110VDC 120VDC 150VDC
Output Current
8-50A
Input Voltage
AC100-240V
Brand
SSPELE
Place of Origin
China
SPECIFICATIONS
OUTPUT  
Model SHAF-1200-60 SHAF-1200-150 SHAF-1200-24 SHAF-1200-110 SHAF-1200-36 SHAF-1200-48
DC Voltage 60V 150V 24V 110V 36V 48V
Rated Current 20A 8A 50A 11A 33A 25A
Current Range 0-20A 0-8A 0-50A 0-11A 0-33A 0-25A
Rated Power 1200W 1200W 1200W 1200W 1200W 1200W
Ripple&Noise 200mVp-p 240mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p
Voltage Adj. Range 0-60V 0-150V 0-24V 0-110V 0-36V 0-48V
Voltage Tolerance ±2% ±1% ±1% ±1% ±1% ±1%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup,Rise,Hold Up Time 1.5s,50ms,20msat full load
   
INPUT  
Voltage Range AC100-240V
AC Current 7A/115V3.5A/230V
Efficiency 90% 90% 90% 90% 90% 90%
Inrush Current  
Leakage Current  
   
PROTECTION  
Over Load 105-135%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage            
Over Temp. ≥55℃Fan On≤45℃Fan Off ≥70℃ Output Cutout
   
ENVIRONMENT  
Working Temp.Humidity -25℃~+50℃; 20%~90%RH
Storage Temp.Humidity -20℃~+85℃; 10%~95%RH
Temp.Coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz,2G 10min,/11cycle,60min,each axes
   
SAFETY  
Withstand Voltage I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC
Isolation Resistance I/P-O/P,I/P-FG,I/P-FG:500VDC/100MΩ
   
STANDARD  
Safety Standard UL1950
EMCStandard CISPR22(EN 55022),IEC1000-4,2,3,4,5,6,8,11 IEC1000-3-2
   
OTHERS  
Dimension 268*130*40mm(L*W*H)
Weight 2.8kg
   
NOTE  
1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2.Tolerance:includes set up tolerance,line regulation and load regulation 3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ&47μ parallel capacitor. 4.Line regulation:min&max voltage of the rated load. 5.Load regulation:load from 0 to 100%