4000W 36VDC to 300VDC 310VDC 320VDC 350VDC 360VDC 400VDC 420VDC 450VDC 500VDC 520VDC 550VDC 600VDC 650VDC 700VDC 750VDC 800VDC Booster Converter DC Power Supply
Features: High efficiency, high reliability 100% full load and machine test Protection characteristics: short circuit/ov
- Output Power
- 4000W
- Output Voltage
- 300VDC 310VDC 320VDC 350VDC 360VDC 400VDC 420VDC 450VDC 500VDC 520VDC 550VDC 600VDC 650VDC 700VDC 750VDC 800VDC
- Input Voltage
- 36VDC
- Brand
- SSPELE
Features:
- High efficiency, high reliability
- 100% full load and machine test
- Protection characteristics: short circuit/overload/pressure
- Built-in dc electric fan forced air cooling
- Size: 440*350*130mm(L*W*H)
| model | DD4000/36 -120 |
DD4000/36 -300 |
DD4000/36 -24 |
DD4000/36 -150 |
DD4000/36 -250 |
DD4000/36 -280 |
DD4000/36 -200 |
DD4000/36 -220 |
DD4000/36 -100 |
DD4000/36 -64 |
|
| output | Dc output voltage | 120V | 300V | 24V | 150V | 250V | 280V | 200V | 220V | 100V | 64V |
| Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Rated output current | 33A | 13.3A | 166A | 26.6A | 16A | 14.2A | 20A | 18A | 40A | 62.5A | |
| Output current range | 0-33A | 0-13.3A | 0-166A | 0-26.6A | 0-16A | 0-14.2A | 0-20A | 0-18A | 0-40A | 0-62.5A | |
| Output power | 4000W | 4000W | 4000W | 4000W | 4000W | 4000W | 4000W | 4000W | 4000W | 4000W | |
| Ripple and the noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
| Dc voltage adjustable scope | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | |
| Start, rise, keep time | 1-2s | ||||||||||
| input | Input voltage range | 36VDC | |||||||||
| Frequency | |||||||||||
| Exchange input current | None | ||||||||||
| efficiency | 80% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | |
| Impulse current | |||||||||||
| Leakage current | |||||||||||
| Protection characteristics | Overload protection | 115%~135% | |||||||||
| Protection way: cut off the output,reset, automatic recovery | |||||||||||
| Overvoltage protection | 120%~140% | ||||||||||
| Protection way: hiccups, auto recovery mode | |||||||||||
| environment | Working temperature, humidity | -30℃~+65℃;20%~90 %RH | |||||||||
| Keep temperature, humidity | -40℃~+85℃;10%~95 %RH | ||||||||||
| Vibrate resistance | 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis | ||||||||||
| security | Compression sex | L/P-O/P: 1.5KVAC , L/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC (one minute) | |||||||||
| Insulation resistance | L/P-O/P, L/P-FG,O/P-FG : 500VDC / 100M ohms | ||||||||||
| standards | Insulation resistance | Accord with EN55015 EN61547 EN61000-3-2 EN6100-3-3 |
|||||||||
| EMC standard | Accord with EN61347-1 EN61347-2-13 |
||||||||||
| other | weight | 20Kg | |||||||||
| packaging | 1pcs/20kg | ||||||||||