7500W 48VDC to 300VDC 310VDC 320VDC 330VDC 340VDC 350VDC 360VDC 370VDC 380VDC 390VDC 400VDC 410VDC 420VDC 430VDC 450VDC 460VDC 470VDC 500VDC Booster Converter DC Power Supply
Features: High efficiency, high reliability 100% full load and machine test Protection characteristics: short circuit/ov
- Output Power
- 7500W
- Output Voltage
- 300VDC 310VDC 320VDC 330VDC 340VDC 350VDC 360VDC 370VDC 380VDC 390VDC 400VDC 410VDC 420VDC 430VDC 450VDC 460VDC 470VDC 500VDC
- Input Voltage
- 48VDC
- Brand
- SSPELE
- Payment
- T/T,Payment
- Place of Origin
- China
Features:
- High efficiency, high reliability
- 100% full load and machine test
- Protection characteristics: short circuit/overload/pressure
- Built-in dc electric fan forced air cooling
- Size: 440*350*130mm(L*W*H)
| model | DD7500/48 -400 |
DD7500/48 -300 |
DD7500/48 -150 |
DD7500/48 -350 |
DD7500/48 -250 |
DD7500/48 -280 |
DD7500/48 -200 |
DD7500/48 -220 |
DD7500/48 -100 |
DD7500/48 -64 |
|
| output | Dc output voltage | 400V | 300V | 150V | 350V | 250V | 280V | 200V | 220V | 100V | 64V |
| Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Rated output current | 18.7A | 25A | 50A | 21A | 30A | 26.7A | 37.5A | 34A | 75A | 117A | |
| Output current range | 0-18.7A | 0-25A | 0-50A | 0-21A | 0-30A | 0-26.7A | 0-37.5A | 0-34A | 0-75A | 0-117A | |
| Output power | 7500W | 7500W | 7500W | 7500W | 7500W | 7500W | 7500W | 7500W | 7500W | 7500W | |
| Ripple and the noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
| Dc voltage adjustable scope | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | |
| Start, rise, keep time | 1-2s | ||||||||||
| input | Input voltage range | 48VDC | |||||||||
| Frequency | |||||||||||
| Exchange input current | None | ||||||||||
| efficiency | 80% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | |
| Impulse current | |||||||||||
| Leakage current | |||||||||||
| Protection characteristics | Overload protection | 115%~135% | |||||||||
| Protection way: cut off the output,reset, automatic recovery | |||||||||||
| Overvoltage protection | 120%~140% | ||||||||||
| Protection way: hiccups, auto recovery mode | |||||||||||
| environment | Working temperature, humidity | -30℃~+65℃;20%~90 %RH | |||||||||
| Keep temperature, humidity | -40℃~+85℃;10%~95 %RH | ||||||||||
| Vibrate resistance | 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis | ||||||||||
| security | Compression sex | L/P-O/P: 1.5KVAC , L/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC (one minute) | |||||||||
| Insulation resistance | L/P-O/P, L/P-FG,O/P-FG : 500VDC / 100M ohms | ||||||||||
| standards | Insulation resistance | Accord with EN55015 EN61547 EN61000-3-2 EN6100-3-3 |
|||||||||
| EMC standard | Accord with EN61347-1 EN61347-2-13 |
||||||||||
| other | weight | 20Kg | |||||||||
| packaging | 1pcs/20kg | ||||||||||
| note | |||||||||||