180-260VAC to 8KW 10KW 15KW 20KW 24VDC 36VDC 48VDC 60VDC 80VDC 100VDC 110VDC 150VDC 200VDC 220VDC 250VDC 300VDC 400VDC 500VDC 550VDC 600VDC 700VDC 750VDC 800VDC 850VDC 900VDC 1000VDC Adjustable Industrial Power Supply
8KW 10KW 15KW 20KW 24VDC 36VDC 48VDC 60VDC 70VDC 72VDC 80VDC 90VDC 100VDC 110VDC 120VDC 150VDC 160VDC 200VDC 220VDC 250VDC 280VDC 300VDC 400VDC 440VDC 500VDC 550VDC 600VDC 660VDC 700VDC 750VDC 800VDC 850VDC 900VDC 1000VDC Output Adjustable Industrial Power Supply Support In Parallel
- Output Power
- 8KW 10KW 15KW 20KW
- Output Voltage
- 24VDC 36VDC 48VDC 60VDC 70VDC 72VDC 80VDC 90VDC 100VDC 110VDC 120VDC 150VDC 160VDC 200VDC 220VDC 250VDC 280VDC 300VDC 400VDC 440VDC 500VDC 550VDC 600VDC 660VDC 700VDC 750VDC 800VDC 850VDC 900VDC 1000VDC Adjustable
- Output Current
- Support In parallel
- Input Voltage
- AC180-260V
- Brand
- SSPELE
- Application
- Power DC screen system,industrial control automation, communications, military research, battery charging and aging test equipment.
- Quality
- Government Engineering,ISO9001,CE&Rohs,UL
- Payment
- T/T, L/C, Western Union,Paypal,MoneyGram
- Quantity
- 5000 Sets Per Month
- Packing
- Suitable Packing For Sea / Air Transport
- Material
- Aluminum,PCB
- Place of Origin
- Zhejiang,China
- Ripple&Noise
- 200mVp-p
Features:
- High efficiency, high reliability
- For AC power supply input global
- 100% full load and machine test
- Protection characteristics: short circuit/overload/pressure
- Built-in dc electric fan forced air cooling
- Built-in fan switch control
- PFC correction, built-in distance open/shutdown and voltage compensation signal interface
- Size: 550*500*320mm(L*W*H)
- Output Voltage Customized: 0-24/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300V DC Adjustable
| model | SHA-18000 -300 |
SHA-18000 -200 |
SHA-18000 -150 |
SHA-18000 -100 |
SHA-18000 -80 |
SHA-18000 -48 |
SHA-18000 -60 |
|
| output | Dc output voltage | 0-300V | 0-200V | 0-150V | 0-100V | 0-80V | 0-48V | 0-60V |
| Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Rated output current | 60A | 90A | 120A | 180A | 225A | 375A | 300A | |
| Output current range | 0-60A | 0-90A | 0-120A | 0-180A | 0-225A | 0-375A | 0-300A | |
| Output power | 18000W | 18000W | 18000W | 18000W | 18000W | 18000W | 18000W | |
| Ripple and the noise | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | |
| Dc voltage adjustable scope | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | |
| Start, rise, keep time | 200ms,50ms,30ms full Loaded with 230VAC | |||||||
| input | Input voltage range | 200-240VAC | ||||||
| Frequency | 50-60Hz | |||||||
| Exchange input current | None | |||||||
| efficiency | 86% | 82% | 83% | 85% | 86% | 86% | 86% | |
| Impulse current | None | |||||||
| Leakage current | <3.5mA/240VAC | |||||||
| Protection characteristics | Overload protection | 105%~135% | ||||||
| Protection way: cut off the output,reset, automatic recovery | ||||||||
| Overvoltage protection | 120%~140% | |||||||
| Protection way: Folded current limit ,auto recovery mode | ||||||||
| environment | Working temperature, humidity | -10℃~+50℃;90 %RH | ||||||
| Keep temperature, humidity | -20℃~+70℃;90%(40±2℃) | |||||||
| Vibrate resistance | 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis | |||||||
| security | Compression sex | L/P-O/P: 1.5KVAC , L/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC (one minute) | ||||||
| Insulation resistance | L/P-O/P, L/P-FG,O/P-FG : 500VDC / 100M ohms | |||||||
| standards | Insulation resistance | Accord with GB4943,UL60950,EN60950 |
||||||
| EMC standard | Accord with EN55022, Class A |
|||||||
| other | weight | 30Kg | ||||||
| packaging | 1set/30kg | |||||||
| note | All the parameters in has not specified, all is in 220 VAC voltage input, rated load and 25 ℃conditions measuring income value. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. Specific output current see output drop forehead curve. |
|||||||


