1800W Output Adjustable Switch Mode Power Supply
Output Power: 1800W
Output Voltage: 0-30V DC Adjustable
Output Current: 60A
                                    - Output Power
- 1800W
- Output Voltage
- 0-12/24/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300/400/500/600V DC Adjustable
- Output Current
- 0-130A
- Input Voltage
- AC200-240V
- Brand
- SSPELE
- Application
- Hospital,Engineering Project,Electric Lab,LED Lighting etc.
- Quality
- Government Engineering,ISO9001,CE&Rohs,UL
- Payment
- T/T, L/C, Western Union,Paypal,MoneyGram
- Quantity
- 100000 PCS Per Month
- Packing
- Suitable Packing For Sea / Air Transport
- Material
- Aluminum,PCB
- Place of Origin
- Zhejiang,China
- Ripple&Noise
- 250mVp-p
Features:
- High efficiency, high reliability
- For AC power supply input global
- 100% full load and machine test
- Protection characteristics: short circuit/overload/pressure
- Built-in dc electric fan forced air cooling
- Built-in fan switch control
- PFC correction, built-in distance open/shutdown and voltage compensation signal interface
- Size: 295*145*145mm(L*W*H)
- Output Voltage Customized: 0-12/24/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300V DC Adjustable
| model | SHA-1800 -300 | SHA-1800 -200 | SHA-1800 -150 | SHA-1800 -100 | SHA-1800 -80 | SHA-1800 -48 | SHA-1800 -60 | |
| output | Dc output voltage | 0-300V | 0-200V | 0-150V | 0-100V | 0-80V | 0-48V | 0-60V | 
| Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Rated output current | 6A | 9A | 12A | 18A | 22A | 37.5A | 30A | |
| Output current range | 0-6A | 0-9A | 0-12A | 0-18A | 0-22A | 0-37.5A | 0-30A | |
| Output power | 1800W | 1800W | 1800W | 1800W | 1800W | 1800W | 1800W | |
| Ripple and the noise | 250mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | |
| Dc voltage adjustable scope | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | |
| Start, rise, keep time | 200ms,50ms,30ms full Loaded with 230VAC | |||||||
| input | Input voltage range | 200-240VAC | ||||||
| Frequency | 47-63Hz | |||||||
| Exchange input current | None | |||||||
| efficiency | 86% | 82% | 83% | 85% | 86% | 86% | 86% | |
| Impulse current | 25A/115V 50A/230V | |||||||
| Leakage current | <3.5mA/240VAC | |||||||
| Protection characteristics | Overload protection | 115%~135% | ||||||
| Protection way: cut off the output,reset, automatic recovery | ||||||||
| Overvoltage protection | 120%~140% | |||||||
| Protection way: hiccups, auto recovery mode | ||||||||
| environment | Working temperature, humidity | -10℃~+60℃;20%~90 %RH | ||||||
| Keep temperature, humidity | -20℃~+85℃;10%~95 %RH | |||||||
| Vibrate resistance | 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis | |||||||
| security | Compression sex | L/P-O/P: 1.5KVAC , L/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC (one minute) | ||||||
| Insulation resistance | L/P-O/P, L/P-FG,O/P-FG : 500VDC / 100M ohms | |||||||
| standards | Insulation resistance | Accord with UL1012 | ||||||
| EMC standard | Accord with EN55022, classA | |||||||
| other | weight | 7Kg | ||||||
| packaging | 2pcs/14kg | |||||||
| note | All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃conditions measuring income value. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. Specific output current see output drop forehead curve. | |||||||
 
            