AC110-240V to 2000W 0-150VDC Adjustable PFC Power Supply
SPECIFICATIONS OUTPUT Model SHAF-2000-60 SHAF-2000-150 SHAF-2000-24 SHAF-2000-110 SHAF-2000-36 SHAF-2000-48 DC Vo
- Output Power
- 2000W
- Output Voltage
- 0-150VDC
- Output Current
- 13A
- Input Voltage
- AC110-240V
- Brand
- SSPELE
- Place of Origin
- China
| SPECIFICATIONS | ||||||||||
| OUTPUT | ||||||||||
| Model | SHAF-2000-60 | SHAF-2000-150 | SHAF-2000-24 | SHAF-2000-110 | SHAF-2000-36 | SHAF-2000-48 | ||||
| DC Voltage | 60V | 150V | 24V | 110V | 36V | 48V | ||||
| Rated Current | 33A | 13.3A | 80A | 18A | 55A | 41A | ||||
| Current Range | 0-33A | 0-13.3A | 0-80A | 0-18A | 0-55A | 0-41A | ||||
| Rated Power | 2000W | 2000W | 1000W | 2000W | 2000W | 2000W | ||||
| Ripple&Noise | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | ||||
| Voltage Adj. Range | 0-60V | 0-150V | 0-24V | 0-110V | 0-36V | 0-48V | ||||
| Voltage Tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ||||
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||
| Load Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||
| Setup,Rise,Hold Up Time | 1.5s,50ms,20msat full load | |||||||||
| INPUT | ||||||||||
| Voltage Range | AC110-240V | |||||||||
| AC Current | ||||||||||
| Efficiency | 90% | 90% | 90% | 90% | 90% | 90% | ||||
| Inrush Current | ||||||||||
| Leakage Current | ||||||||||
| PROTECTION | ||||||||||
| Over Load | 115% | |||||||||
| Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
| Over Voltage | ||||||||||
| Over Temp. | ≥55℃Fan On≤45℃Fan Off ≥70℃ Output Cutout | |||||||||
| ENVIRONMENT | ||||||||||
| Working Temp.Humidity | -25℃~+50℃; 20%~90%RH | |||||||||
| Storage Temp.Humidity | -20℃~+85℃; 10%~95%RH | |||||||||
| Temp.Coefficient | ±0.03%/℃(0~50℃) | |||||||||
| Vibration | 10~500Hz,2G 10min,/11cycle,60min,each axes | |||||||||
| SAFETY | ||||||||||
| Withstand Voltage | I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC | |||||||||
| Isolation Resistance | I/P-O/P,I/P-FG,I/P-FG:500VDC/100MΩ | |||||||||
| STANDARD | ||||||||||
| Safety Standard | UL1950 | |||||||||
| EMCStandard | CISPR22(EN 55022),IEC1000-4,2,3,4,5,6,8,11 IEC1000-3-2 | |||||||||
| OTHERS | ||||||||||
| Dimension | 280*140*65mm(L*W*H) | |||||||||
| Weight | 3.5kg | |||||||||
| NOTE | ||||||||||
| 1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2.Tolerance:includes set up tolerance,line regulation and load regulation 3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ&47μ parallel capacitor. 4.Line regulation:min&max voltage of the rated load. 5.Load regulation:load from 0 to 100% | ||||||||||